Click here to close
Hello! We notice that you are using Internet Explorer, which is not supported by Xenbase and may cause the site to display incorrectly.
We suggest using a current version of Chrome,
FireFox, or Safari.
PLoS One
2014 Jan 01;96:e99615. doi: 10.1371/journal.pone.0099615.
Show Gene links
Show Anatomy links
Label-free determination of hemodynamic parameters in the microcirculaton with third harmonic generation microscopy.
Dietzel S
,
Pircher J
,
Nekolla AK
,
Gull M
,
Brändli AW
,
Pohl U
,
Rehberg M
.
???displayArticle.abstract???
Determination of blood flow velocity and related hemodynamic parameters is an important aspect of physiological studies which in many settings requires fluorescent labeling. Here we show that Third Harmonic Generation (THG) microscopy is a suitable tool for label-free intravital investigations of the microcirculation in widely-used physiological model systems. THG microscopy is a non-fluorescent multi-photon scanning technique combining the advantages of label-free imaging with restriction of signal generation to a focal spot. Blood flow was visualized and its velocity was measured in adult mouse cremaster muscle vessels, non-invasively in mouse ear vessels and in Xenopus tadpoles. In arterioles, THG line scanning allowed determination of the flow pulse velocity curve and hence the heart rate. By relocating the scan line we obtained velocity profiles through vessel diameters, allowing shear rate calculations. The cell free layer containing the glycocalyx was also visualized. Comparison of the current microscopic resolution with theoretical, diffraction limited resolution let us conclude that an about sixty-fold THG signal intensity increase may be possible with future improved optics, optimized for 1200-1300 nm excitation. THG microscopy is compatible with simultaneous two-photon excited fluorescence detection. It thus also provides the opportunity to determine important hemodynamic parameters in parallel to common fluorescent observations without additional label.
???displayArticle.pubmedLink???
24933027
???displayArticle.pmcLink???PMC4059650 ???displayArticle.link???PLoS One
Figure 2. THG line scanning in the mouse cremaster muscle.(a) Scheme of the process. Erythrocytes passing by cause a signal in each of the four sequentially scanned lines, recorded at time points T1 to T4. Lines are put together in an x-t-representation (bottom). Here, each erythrocyte moving along the scanned line shows a continuously advancing position, resulting in a streak of signal with a measurable angle. The orientation of the individual lines is the same in all following x-t-representations. (b) x-t-representation from a capillary, (câf): Comparison of various evaluations on the same 30 µm cremaster venule. (c) x-t-representation. (d) Fourier-transformation of the x-t-representation which is partly shown in c. The calculated average velocity in this example was 1.5 mm/s. (e) Comparison of velocities measured with THG line scan visualized in C (1.56 mm/s±0.22 s.d.) and with fluorescent beads and a camera (1.65 mm/s±0.50 s.d., Figure S1) in the same venule. Horizontal lines indicate mean values. Double line scans (ds) scanned two parallel lines alternately, with ds-cen more centrally (1.56 mm/s±0.17) and ds-per more peripherally (1.41 mm/s±0.12). Note higher velocity in ds-cen (pâ=â0.037, t-test). (f) LS-PIV measurements with the line scanning data set visualized in C. Two of seven seconds continuous run are shown with a data point every 16 ms. Average speed was 1.3 mm/s±0.07 s.d. The inset shows the position of the scan line (red) in this venule, visualized by THG. (g) LS-PIV measurements at the center of a 50 µm arteriole from the same cremaster muscle with a data point every 3 ms. Mean velocity over 11.9 seconds (19895 data points) was 2.35 mm/s, heart rate was â¼250 beats/min.
Figure 3. THG microscopy in the mouse ear.(a,b) Intravital imaging in different animals with arteriole (A), venule (V) and nerve fiber (N) running in parallel. In addition to the THG signal (cyan) SHG (red) is displayed. The arrow points to a typical linear vessel wall signal found only in arterioles. Scale bars 20 µm. The declining THG signal strength in more axial parts of a vessel are easiest to recognize in the arteriole in (a) and the venule in (b). (câe) Flow velocity profile measurements by THG shifted line scan in the venule shown in b. (c) Clippings from x-t-representations of 12 parallel scan lines spaced 4.4 µm from each other. Lines 1, 11 and 12 were located in the vessel wall and thus show no movement. Note the shallower angles (faster velocity) and decreased intensity in the central scans. (d) Measurements derived from c by manual evaluation of individual streaks (circles) with mean values (horizontal lines) and mean values from LS-PIV calculations (diamonds). Scan lines 2 (0 µm) to 10 (35.2 µm) from (c) are included. Manually measured velocities revealed significant differences between the scan lines (p<0.0001, ANOVA) with significant differences between all direct neighbors (p<0.05 or smaller, post hoc Newman-Keuls test). For scan line 2 (0 µm), only a part of the x-t-representation showed blood flow. Apparently this line was close to the vessel wall so that slight movement could shift it outside. No reasonable LS-PIV average could thus be obtained. LS-PIV evaluations of the other scan lines confirmed significantly different blood flow velocities in general (p<0.0001; ANOVA, nâ=â88 for each line) and for all direct neighbors (****), except for the two central lines. (e) Measurements by manual evaluation for the arteriole shown in (b) Velocity measurements were significantly different between 0 and 4.4 µm lines (pâ=â0.0075) and between 8.8 and 13.2 µm lines (pâ=â0.0129). (f) LS-PIV results for the same arteriole. Only systolic maxima and diastolic minima (circles) and the mean values over all 3.2-millisecond-spaced 179 measurements (line) are shown. In the first scan line systole and diastole could not be identified reliably, therefore only the mean is given. Velocity differences between neighboring scan lines were all significant (p<0.0001) except between 13.2 and 17.6 µm (pâ=â0.87).
Figure 4. THG line scan measurement of the blood flow velocity in the tail artery of a stage 45 Xenopus laevis larvae (4 days post fertilization).(a) xt-representation showing 680 lines of the recording, representing the first 0.46 s of the graph in (b). (b) LS-PIV results from the two seconds depicted show values oscillating between 4 mm/s systolic and 0.9 mm/s diastolic. The higher peaks are determined by ventricular heart contractions. Arrows mark the first three secondary peaks (see main text). Calculation of the heart rate yielded a value of about 200 beats per minute, the vessel diameter was 45 µm.
Figure 5. Visualization of the cell free layer in the cremaster muscle by THG with mirror-enhanced signals[29]. (a) RBCs are excluded from a gap near the vessel wall. Boxed area magnified on the right. 1, vessel wall. 2, THG free gap. 3, RBC tracks. (bâd) Image of the same area after injection of fluorescently labeled 40 kDa dextran. THG in gray (b,c), dextran fluorescence in green (c,d). The THG free gap is unchanged in width. Contrary to the erythrocytes, this small dextran infiltrates the cell free layer. Scale bar 20 µm. A movie of this vessel is shown in Movie S1.
Figure 1. Intravital THG imaging of blood flow in the mouse cremaster muscle.Images were scanned with lines from top to bottom and line addition from right to left. Arrows indicate direction of blood flow. All scale bars 20 µm. (a) Combined SHG (red) and THG (cyan) image with mirror-enhanced signals [29]. In the left vessel, RBCs flow with the direction of added scan lines, therefore some are elongated to intense streaks. Image brightness was adjusted to allow simultaneous visualization of low and high intensities with a gamma value of 2. (b) Flow in this capillary was with the scan direction from right to left, therefore RBCs appear elongated. (c) Flow in this capillary was against scan direction, from left to right, RBCs therefore appear much shorter (compare scale bars). (d) RBCs flowing in a â¼25 µm vessel. RBC shapes in the image are optically deformed by the relation of blood flow velocity and the scanning process (see main text). (e) THG recording of RBCs suitable for blood flow velocity measurement. Scheme on top illustrates the principle with scanlines 0â3, see Methods for details. In the example shown scan speed was 800 lines per second, the temporal distance between two lines was thus 1.25 ms. Pixel size was 0.31 µm. Blood flow velocity was determined to be 0.75 mm/s.
Autio,
Spatial frequency-based analysis of mean red blood cell speed in single microvessels: investigation of microvascular perfusion in rat cerebral cortex.
2011, Pubmed
Autio,
Spatial frequency-based analysis of mean red blood cell speed in single microvessels: investigation of microvascular perfusion in rat cerebral cortex.
2011,
Pubmed
Baez,
An open cremaster muscle preparation for the study of blood vessels by in vivo microscopy.
1973,
Pubmed
Becker,
Endothelial glycocalyx and coronary vascular permeability: the fringe benefit.
2010,
Pubmed
Bihari,
Optimized dispersion of nanoparticles for biological in vitro and in vivo studies.
2008,
Pubmed
BLOCH,
A quantitative study of the hemodynamics in the living microvascular system.
1962,
Pubmed
Buerkle,
Selective inhibition of cyclooxygenase-2 enhances platelet adhesion in hamster arterioles in vivo.
2004,
Pubmed
Chaigneau,
Two-photon imaging of capillary blood flow in olfactory bulb glomeruli.
2003,
Pubmed
Chang,
Multi-photon resonance enhancement of third harmonic generation in human oxyhemoglobin and deoxyhemoglobin.
2010,
Pubmed
Chen,
In vivo harmonic generation biopsy of human skin.
2009,
Pubmed
Cosgrove,
Imaging of perfusion using ultrasound.
2010,
Pubmed
Cox,
Practical limits of resolution in confocal and non-linear microscopy.
2004,
Pubmed
Damon,
A comparison between mean blood velocities and center-line red cell velocities as measured with a mechanical image streaking velocitometer.
1979,
Pubmed
De Backer,
Monitoring the microcirculation.
2012,
Pubmed
Farrar,
In vivo imaging of myelin in the vertebrate central nervous system using third harmonic generation microscopy.
2011,
Pubmed
Goldsmith,
The Microcirculatory Society Eugene M. Landis Award lecture. The microrheology of human blood.
1986,
Pubmed
Helmchen,
Chapter 10. In vivo measurements of blood flow and glial cell function with two-photon laser-scanning microscopy.
2008,
Pubmed
Hou,
Blood pressures and heart rate during larval development in the anuran amphibian Xenopus laevis.
1995,
Pubmed
,
Xenbase
Jain,
Measuring angiogenesis and hemodynamics in mice.
2013,
Pubmed
Kälin,
An in vivo chemical library screen in Xenopus tadpoles reveals novel pathways involved in angiogenesis and lymphangiogenesis.
2009,
Pubmed
,
Xenbase
Kamoun,
Simultaneous measurement of RBC velocity, flux, hematocrit and shear rate in vascular networks.
2010,
Pubmed
Khandoga,
In vivo imaging and quantitative analysis of leukocyte directional migration and polarization in inflamed tissue.
2009,
Pubmed
Kim,
Temporal and spatial variations of cell-free layer width in arterioles.
2007,
Pubmed
Kim,
Line-scanning particle image velocimetry: an optical approach for quantifying a wide range of blood flow speeds in live animals.
2012,
Pubmed
Kleinfeld,
Fluctuations and stimulus-induced changes in blood flow observed in individual capillaries in layers 2 through 4 of rat neocortex.
1998,
Pubmed
Krötz,
A sulfaphenazole-sensitive EDHF opposes platelet-endothelium interactions in vitro and in the hamster microcirculation in vivo.
2010,
Pubmed
Lee,
Noninvasive in vitro and in vivo assessment of epidermal hyperkeratosis and dermal fibrosis in atopic dermatitis.
2009,
Pubmed
Millard,
Third-harmonic generation microscopy by use of a compact, femtosecond fiber laser source.
1999,
Pubmed
Oron,
Depth-resolved structural imaging by third-harmonic generation microscopy.
2004,
Pubmed
Pfeffer,
Multimodal nonlinear optical imaging of collagen arrays.
2008,
Pubmed
Pircher,
Hydrogen sulfide-releasing aspirin derivative ACS14 exerts strong antithrombotic effects in vitro and in vivo.
2012,
Pubmed
Poelma,
Accurate blood flow measurements: are artificial tracers necessary?
2012,
Pubmed
Popel,
Microcirculation and Hemorheology.
2005,
Pubmed
Pries,
Microvascular blood flow resistance: role of endothelial surface layer.
1997,
Pubmed
Rehberg,
Label-free 3D visualization of cellular and tissue structures in intact muscle with second and third harmonic generation microscopy.
2011,
Pubmed
Rehberg,
Signal improvement in multiphoton microscopy by reflection with simple mirrors near the sample.
2010,
Pubmed
Reitsma,
The endothelial glycocalyx: composition, functions, and visualization.
2007,
Pubmed
Rosenblum,
Erythrocyte velocity and a velocity pulse in minute blood vessels on the surface of the mouse brain.
1969,
Pubmed
Sarelius,
Direct measurement of microvessel hematocrit, red cell flux, velocity, and transit time.
1982,
Pubmed
Schaller,
Nonlinear chemical imaging microscopy: near-field third harmonic generation imaging of human red blood cells.
2000,
Pubmed
Schwerte,
Understanding cardiovascular physiology in zebrafish and Xenopus larvae: the use of microtechniques.
2003,
Pubmed
,
Xenbase
Smith,
Near-wall micro-PIV reveals a hydrodynamically relevant endothelial surface layer in venules in vivo.
2003,
Pubmed
Sperandio,
Ontogenetic regulation of leukocyte recruitment in mouse yolk sac vessels.
2013,
Pubmed
Sumen,
Intravital microscopy: visualizing immunity in context.
2004,
Pubmed
Tangelder,
Wall shear rate in arterioles in vivo: least estimates from platelet velocity profiles.
1988,
Pubmed
Thayil,
Long-term imaging of mouse embryos using adaptive harmonic generation microscopy.
2011,
Pubmed
Tsai,
In vivo optical virtual biopsy of human oral mucosa with harmonic generation microscopy.
2011,
Pubmed
Vink,
Capillary endothelial surface layer selectively reduces plasma solute distribution volume.
2000,
Pubmed
Vink,
Identification of distinct luminal domains for macromolecules, erythrocytes, and leukocytes within mammalian capillaries.
1996,
Pubmed
Weigelin,
Intravital third harmonic generation microscopy of collective melanoma cell invasion: Principles of interface guidance and microvesicle dynamics.
2012,
Pubmed
Weinbaum,
The structure and function of the endothelial glycocalyx layer.
2007,
Pubmed
Yu,
High-resolution three-photon biomedical imaging using doped ZnS nanocrystals.
2013,
Pubmed
Ziegler,
Angiopoietin 2 mediates microvascular and hemodynamic alterations in sepsis.
2013,
Pubmed