Figure 1. Temperature dependence of development progression in fly and frog embryos
A table representing D. melanogaster developmental scoring event names and sequential score codes used throughout this paper.X. laevis developmental scoring and codes used throughout this paper.Shown here is a schematic depicting how time Ï intervals are determined based on beginning and ending scores. Plotted also are all mean time intervals from t = 0, defined as 14th syncytial cleavage, to reach various developmental scores in D. melanogaster embryos. Error bars in time indicate standard deviation among replicates (n = 2â13 biological replicates per temperature). Error bars in temperature represent the standard error (± 0.5°C) of the thermometer used when recording temperature.As (C) but for X. laevis, since t = 0 (3rd cleavage) at temperatures ranging from 10.3°C to 33.1°C (n = 1â23 biological replicates per temperature).
|
|
Figure EV1. Scored developmental events and coefficient of variation (CV) analysis
Sketches of 12 developmental scores determined to be the most reproducible, in D. melanogaster. Please see Materials and Methods and Movie EV1 for definition of scoring criteria.Seven additional developmental events in fly embryos that we did not pursue due to poor reproducibility i.e. cut score. The number score code is used in the following CV analysis.We calculated CVs using preliminary data for every developmental time interval between the 19 scores (described in Materials and Methods) we considered investigating (Dataset EV1). CVs are calculated for each of the 6 different temperatures (n = 3â5 biological replicates per temperature), and the mean CV is then displayed for each interval. CVâs are displayed as percentages. The 11 most reproducible intervals for neighboring scores (diagonal) are shown in green. Intervals shown in red had their associated score (numbers) cut from our investigation.Sketches of 12 developmental event we investigated in X. laevis determined most reproducible. Please see Materials and Methods and Movie EV2 for definition of scoring criteria.As (B) but for four additional frog developmental events not included in our final analysis.As (C) but for intervals calculated from early data, between 16 frog developmental scores considered (described in Material and Methods) averaged over 16 temperatures (n = 2â6 biological replicates per temperature) (Dataset EV2). The 11 most reproducible intervals for neighboring scores (diagonal) are shown in green.
|
|
Figure 2. Apparent activation energies vary significantly between developmental intervals
Arrhenius plots for two examples of developmental intervals (DâE, EâF) in D. melanogaster. Blue data points are the means of replicates for viable temperatures that survive until First Breath. Red data represent more extreme temperature values where embryos do not survive until First Breath. A linear regression (solid black line, n = 66, 65 independent biological measurements, respectively) was fit over the core temperature range (14.3â27°C), from which Ea was calculated and reported with its 68% confidence interval. Error bars in temperature represent the standard error (± 0.5°C) of the thermometer used when recording temperature. Error bars in ln(rate) represent standard error (n = 3â13 biological replicates).As (A) but for intervals GâH, KâL in X. laevis. Blue data points represent viable temperatures where embryos survive until Late Neurulation. A linear regression (solid black line, n = 120, 94 independent biological measurements, respectively) was fit over core temperatures spanning 12.2â25.7°C, from which the Ea was calculated and reported in black. Error bars in temperature represent the standard error (± 0.5°C) of the thermometer used when recording temperature. Error bars in ln(rate) represent standard error (n = 1â10 biological replicates).Apparent activation energies in fly calculated from Arrhenius plots (Fig EV2A). The xâaxis is labeled with the developmental interval, marked by start and endpoint. Error bars represent the 68% confidence interval for the activation energy based on linear fit in the Arrhenius plot. Black braces connect examples of developmental intervals that show statistically significant differences in slope (and thus Ea), with respectable power (> 0.8), ***P < 0.001, (Fâtest), (n = 39â60 independent biological measurements).As (C) but for frog Ea calculated from plots shown in Fig EV2B. Magenta brackets represent groupings (all points above the bracket) showing no statistical difference (#) in activation energy (Fâtest), (n = 94â135 independent biological measurements).
|
|
Figure EV2. Arrhenius plots for fly and frog
Shown are Arrhenius plots (similar to Fig 2A) for developmental intervals between 12 adjacent fly developmental scores. Linear fits (solid black line) were calculated from 14.3 to 27°C. The apparent activation energy for each interval is displayed top right of each subplot. Blue data points represent temperatures viable until First Breath. Extreme temperatures that do not survive until our final scores are shown in red. A quadratic (dashed red line) is fit through all the data (red and blue). Error bars in temperature represent the standard error (± 0.5°C) of the thermometer used when recording temperature. Error bars in ln(rate) represent standard error (n = 2â13 biological replicates per temperature).As (A) but using 12 adjacent frog developmental scores. Linear fits are calculated from 12.2 to 25.7°C, used in Fig 2B, (n = 1â23 biological replicates per temperature). Blue data points represent temperatures viable until Late Neurulation.
|
|
Figure EV3. Reanalysis of temperature dependence data in Drosophila melanogaster development from Kuntz and Eisen
Scores Kuntz and Eisen used and abbreviation for the remainder of this figure.Arrhenius plots for durations between adjacent developmental events of Kuntz and Eisenâs data. We fit data for temperatures of 27.5°C and below (dashed red line, i.e., core temperature range) via linear regression (solid blue line). Shown is the apparent activation energy plus/minus the 68% confidence interval. Additionally, we fit the entire temperature range with quadratic (dashed blue line) and linear fits. BIC was also calculated and is shown here as the natural log ratio likelihood for quadratic over linear fit and displayed in black.Apparent activation energies over the core temperature regime are shown. Error bars show the 68% confidence intervals. Black braces point out example developmental intervals that have significantly different apparent activation energies. â**âPâvalue < 0.01, â***âPâvalue < 0.001.Shown are Pâvalues between all developmental intervals. Blue marks Pâvalues above 5Eâ2, purple marks â¤Â 5Eâ2, pink marks â¤Â 1Eâ2, and red marks â¤Â 1Eâ3.Shown are natural log ratio of likelihoods for quadratic over linear fits for all possible developmental intervals, marked by their starting and ending scores, using Kuntz and Eisenâs data over all temperatures. Blue signifies a preference for linearity; red signifies a preference for quadratic behavior.
|
|
|
|
Figure 4. Complexity and nonâidealized behavior of individual enzymes can contribute to nonâidealized behavior of developmental processes
Shown is the methodology used to predict the linear regression for fly development from A to G using empirical parameters from individual intervals and equation (3). Far right, this prediction of ln(k) for the composite network (dashed cyan) is overlaid on the empirical data (blue and red error bars) and linear fit (solid black line) for this developmental interval (AâG). Also shown are the colorâcoded Eas calculated for each fit over the temperature interval 14.3â27°C (n = 60 independent biological measurements). Error bars in temperature represent the standard error (± 0.5°C) of the thermometer used when recording temperature. Error bars in ln(rate) represent standard error (n = 2â12 biological replicates).Shown is a schematic of a multiâreaction network from Stage 1 to Stage n. Comparison of two reaction networks modeling equation (3) with 1,000 coupled reactions, one with randomly selected Ea and A (dashed blue line), the second with Ea and A optimized for maximum curvature at 295°K (dashed orange line). To allow direct comparisons, the yâaxes were scaled to result in overlapping tangents calculated at 295°K (solid black line).As (B), however, the worstâcase model (dashed orange) is compared to biological data (blue and red error bars representing standard error in ln(rate), n = 2â12 biological replicates per temperature) from (A). To allow direct comparisons, the yâaxes were scaled to result in overlapping linear fits over 14.3â27°C (solid black line).Shown is a schematic representing the conversion of NAD+ to NADH via GAPDH catalyzation. GAPDHâs conversion of NAD+ to NADH was monitored with UV/VIS spectroscopy at 340 nm. Plotted here is the Arrhenius plot for this conversion at various temperatures between 5°C and 45°C. Means of technical replicates (blue circles) are fit with a linear fit (dashed blue line) from 15 to 35°C and a quadratic fit (dashed magenta) over the entire temperature range. Standard error is shown as blue error bars (n = 2â4 technical replicates per temperature).
|
|
Figure EV4. Parameters for linear fits and sequential linear model prediction capture temperature dependence of entire embryonic development well
A table showing fly intervals marked by their start and ending scores and their empirically determined prefactors (lnA) and apparent activation energy (Ea) from Fig EV2A.As (A) but for frog prefactors and apparent activation energy calculated empirically from Fig EV2B.Our predictive equation determined in equation (3) for an assumed sequential linear network.Prediction of ln(k) for the composite network (dashed cyan) is overlaid on the empirical data (blue and red error bars) and linear fit (solid black) for this developmental interval (A to K). Also shown are the colorâcoded Eas calculated for each fit over the temperature interval 12.2â25.7°C (n = 100 independent biological measurements). Error bars in temperature represent the standard error (± 0.5°C) of the thermometer used when recording temperature. Error bars in ln(rate) represent standard error (n = 2â10 biological replicates per temperature).
|
|
Figure EV5. Assay of βâgalactosidase activity over its viable temperature range under 0âorder kinetic conditionsPlotted here is the Arrhenius plot for this conversion. Replicates (blue circles) are fit with a linear fit (dashed blue line) from 15 to 35°C and a quadratic fit (dashed magenta) over the entire viable temperature range. Standard error is shown as blue error bars (n = 3 technical replicates per temperature). Reaction was run using 0.25 U/ml βâgalactosidase.
|